Beijer-electronics SCOM RBC EN Manual do Utilizador Página 55

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 64
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 54
Command Reference
Beijer Electronics, MAEN993 55
5.6.23LAU_CONTROL_BUZZER (0x0202)
Buzzer Control
Activates the built-in buzzer, if available.
Supported since Firmware Version
LAUER RBC: 0.0.0.1
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a negative acknowledge message does not con-
tain any status data in response to this command. This response message is only sent,
if there is insufficient data in the command stream.
Maximum Lr for this Command
11
0 1 2 3 4 5 6 7...9 10
0x07 ADR
0x4C 0x41 0x55 0x03 ICHKH 0x02 0x02 Param ICHKD
Param
Value: 0x00: Disable buzzer
0x01: Enable buzzer
Type: Byte
Length: 1
Description: Buzzer control
0 1 2 3 4 5 6 7...9 10
0x06 ADR
0x4C 0x41 0x55 0x03 ICHKH 0x02 0x02 Ret ICHKD
Ret
Value: 0x00: Buzzer disabled
0x01: Buzzer enabled
Type: Byte
Length: 1
Description: Current buzzer state
0 1 2 3 4 5 6 7...8 9
0x15 ADR
0x4C 0x41 0x55 0x02 ICHKH 0x02 0x02 ICHKD
Vista de página 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 63 64

Comentários a estes Manuais

Sem comentários