Vista de página 15
Command Reference
16 Beijer Electronics, MAEN993
5.2 MAN
Manufacturer ID
Requests the manufacturer ID from the device. The manufacturer ID is a short, max.
7 character ASCII-string containing the manufacturer specific code.
For devices manufactured by Beijer Electronics, the returned code is always “LAU”.
Supported since Firmware Version
LAUER RBC: 0.0.0.1
Command Stream
(This command has no data)
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
15
Example
Query the manufacturer ID of the device at address 0.7 (group 0, address 7):
The device at address 0.7 (group 0, address 7) has returned “0x4C 0x41 0x55”, which
represents the ASCII-string “LAU”, indicating that the device is manufactured by
Beijer Electronics:
0 1 2 3 4 5 6
0x07 ADR
0x4D 0x41 0x4E 0x00 ICHKH
0 1 2 3 4 5 6 7...7+[LEN]-1 7+[LEN]
0x06 ADR
0x4D 0x41 0x4E LEN ICHKH Manufacturer ID ICHKD
Manufacturer ID
Value: ASCII characters
Type: String
Length: 0...7
Description: ASCII-string containing the manufacturer ID
0 1 2 3 4 5 6
0x07 0x07 0x4D 0x41 0x4E 0x00 0x15
0 1 2 3 4 5 6 7...9 10
0x06 0x07
0x4D 0x41 0x4E 0x03 0x13 0x4C 0x41 0x55 0x1D