Beijer-electronics iX Panel TA70 EN Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Painel de controlo Beijer-electronics iX Panel TA70 EN. Beijer Electronics iX Panel TA70 EN User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 45
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
iXPanelTA70
Service&MaintenanceManual
English
MAEN012A,2010-12
Vista de página 0
1 2 3 4 5 6 ... 44 45

Resumo do Conteúdo

Página 1 - Service&MaintenanceManual

iXPanelTA70Service&MaintenanceManualEnglishMAEN012A,2010-12

Página 2 - Foreword

Installation3Installation3.1 SpaceRequirements• Installation plate thickness: 1.5 - 9.0 mm (0.06 - 0.35 inch)• Space requirements when installing the

Página 3 - Contents

Installation2.Place the panel cut out where the operator panel is to be situated, draw alongthe outer sides of the holes and cut according to the mark

Página 4

Installation4.Connect the cables in the specified order, according to the drawing and stepsbelow.Caution:• Ensurethattheoperatorpanelandthecontrollersy

Página 5 - 1SafetyPrecautions

Installation3.2.1 ConnectionstotheControllerFor information about the cables to be used when connecting the operator panel tothe controller, please re

Página 6 - 1.5 DismantlingandScrapping

Technical Data4TechnicalDataParameter iX Panel T A70Frontpanel,WxHxD 219x154x6mmMountingdepth 56mm(156mmincludingclearance)Frontpanelseal IP66Rear pan

Página 7 - 2Introduction

Chemical Resistance5 ChemicalResistance5.1 MetalCasingThe frame and casing material is powder-coated aluminum. This powder paintwithstands exposure to

Página 8 - 2.4 DismantlingandScrapping

Chemical Resistance5.2 TouchScreenandOverlay5.2.1 AutotexF157/207Autotex F157 or F207 covers the overlay surrounding the touch screen.SolventR esistan

Página 9 - 2.5 ContactandSupport

Chemical Resistance5.2.2 TouchScreenSurfaceThetouchscreensurfaceonthepanelwithstandsexposuretothefollowingsolvents without visible ch ange:Solvents Ti

Página 10 - 3Installation

Hardware Tests6 HardwareTestsBefore the operator panels are approved for market introduction, they are testedby independent authorities. The iX Panels

Página 11 - 0.5 - 1.0 Nm

Hardware Replacement7 HardwareReplacementThis section contains instructions on how to replace operator panel hardware.Only components included in the

Página 12 - – Connect cable D

ForewordService&MaintenancemanualforiXPanelTA70ForewordThis manual contains detailed information about iX Panel TA70, includingdescriptions of var

Página 13 - BeijerElectronics, MAEN012A

Hardware Replacement7.2 CablesMostoftheoperatorpanelsusethesametypeofflexcableconnectors.connector flangesFlex cable connectorTo release the flex cables

Página 14 - 4TechnicalData

Hardware Replacement7.3 ReplacingtheRearCoverThe following is needed:• Anewrearcover,seeAvailable Spare Parts for iX Panel TA70• AtorxT10screwdriverNo

Página 15 - 5 ChemicalResistance

Hardware Replacement7.4 ReplacingtheDisplay/DisplayCableThe following is needed:• A new display including plastic frame and display cable, seeAvailabl

Página 16 - 5.2 TouchScreenandOverlay

Hardware Replacement7.4.1 SelfTestoftheDisplayTo perform a self test of the display, follow the steps below:1.Start the operator panel in a self test

Página 17 - 5.2.3 AutoflexEB

Hardware Replacement7.5 ReplacingtheCompleteFrontThe following is needed:• Anewfront,seeAvailable Spare P arts for iX Panel T A70• AtorxT10screwdriver

Página 18 - 6 HardwareTests

Hardware Replacement7.6 ReplacingtheBacklightIf the backlight of the iX Panel TA70 is broken, the entire display must be replaced.To replace the displ

Página 19 - 7 HardwareReplacement

Hardware Replacement7.7 AvailableSparePartsforiXPanelTA70Ordernumber Description601009274 COMPLETEFRONTIncludingfrontcover,touchoverlay,gasketsandlabe

Página 20 - 7.2 Cables

Service Menu8ServiceMenuThe service menu for the operator panel can be accessed before a project isdownloaded, or by setting the mode s witches in mod

Página 21 - 7.3 ReplacingtheRearCover

Service Menu8.3.2 Date/TimeUse the Date/Time Settings dialog to set the time zone, date and time for thepanel.8.3.3 EraseProjectThe erase function wil

Página 22 - • AtorxT10screwdriver

Hardware Self Test9 HardwareSelfTestThe self test program can be used to test aspects of operator panel functionalityand the communication ports. To r

Página 23 - 7.4.1 SelfTestoftheDisplay

ContentsContents1 Safety Precautions ... 51.1 General ...

Página 24 - 7.5 ReplacingtheCompleteFront

Hardware Self Test9.1 SelfTestItemsThe following tests, of which some may be dismissed, are performed:Test itemMaybedismissed PlugRS422(short-circuit)

Página 25 - 7.6 ReplacingtheBacklight

Additional Installation Tips10 AdditionalInstallationTipsWhen experiencing communication p roblems in for example noisy environmentsor when operating

Página 26 - Hardware Replacement

Additional Installation Tips10.2 EthernetConnectioninthePanel123451-12-23-38-8RJ45RJ45RJ45RJ45RJ45RJ45RJ45RJ45Industrial EthernetOperator panelOperato

Página 27 - 8ServiceMenu

Additional Installation Tips10.3 ToAchieveBetterEMCProtection• Initially, use the original cabling from Beijer Electronics prima rily.• Use shielded c

Página 28 - 8.3.4 TouchCalibrate

Additional Installation Tips10.4 AmbientTemperatureThe maximum ambient temperature for the operator panel is provided in thespecifications. The ambient

Página 29 - 9 HardwareSelfTest

Additional Installation Tips10.5 SafetyMost of the operator panels are fed with 24 V DC.412434Power supply230 V AC to 24 V DCPower supply230 V AC to 2

Página 30 - 9.1 SelfTestItems

Additional Installation Tips10.6 GalvanicIsolationUSBUSBRS232RS422/485+24 V DC0 VFilterDC/DCgalvanic isolationVCC0 V (GND)DC/ACCFLEthernetInternal ele

Página 31 - 10 AdditionalInstallationTips

Additional Installation Tips10.7 CableandBusTerminationRS485• Use shielded and twisted pair cable. The pair capacitance may not exceed 52.5pF/m and ar

Página 32

Fault Tracing11 FaultTracingThis section includes different fault scenarios and steps to follow to trace the fault.TheiXPanelTA70isnotworkingproperly,

Página 33 - Shielded cable Shielded cable

Fault TracingThetouchscreenismalfunctioningorisnotrespondingatall1.Re-calibrate the touch screen according to the Calibrating the Touch Screen sec-tio

Página 34 - 10.4 AmbientTemperature

Contents10 Additional Installation Tips ... 3110.1 Grounding the Operator Panel ...

Página 35 - 10.5 Safety

Software12 SoftwareThis chapter describes how to maintain and update the software in th e iX Panels.The chapter includes a general descriptio n of the

Página 36 - 10.6 GalvanicIsolation

Software12.2 UpdateSoftwareWhen an update is available, an e-mail is sent to the distributors. The software isalso available on the manufacturer’s web

Página 37 - Inside operator panel

SoftwareRequirementsUpgrading of the operator panel system program requires the following:• APC• An Ethernet connection between the PC and the operato

Página 38 - 11 FaultTracing

Environmental Aspects13 EnvironmentalAspectsThis chapter includes information about the environmental impact of iX Panels.More information can be foun

Página 39

Environmental Aspects13.3 RecyclingThe operator panels consist largely of aluminum. It is a great advantage in terms ofboth resources and the environm

Página 40 - 12 Software

HeadofficeBeijerElectronicsABBox42620124Malmö,Swedenwww.beijerelectronics.com/+4640358600

Página 41 - 12.2 UpdateSoftware

Safety Precautions1SafetyPrecautionsBoth the installer and the owner and/or operator of the operator panel must readand understand this installation m

Página 42 - Requirements

Safety Precautions1.3 DuringUse• Keep the operator panel clean.• Emergency stop and other safety functions may not be controlled from theoperator pane

Página 43 - 13 EnvironmentalAspects

Introduction2IntroductionThis manual describes h ow to maintain the iX Panel TA70.The functions available in iX Developer depend on which operator pan

Página 44 - 13.3 Recycling

Introduction2.2 MaintenanceCarefully read the instruction s before beginning maintenance on the operatorpanel.• Only qualified personnel should carry o

Página 45 - 20124Malmö,Sweden

Introduction2.5 ContactandSupportIf you want to report a fault or have a question about the operator panels, pleasecontact your local supplier or fill

Comentários a estes Manuais