Beijer-electronics iX Panel T70 EN Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Painel de controlo Beijer-electronics iX Panel T70 EN. Beijer Electronics iX Panel T70 EN User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 46
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
iXPanelT70
Service&MaintenanceManual
English
MAEN006,2010-05
Vista de página 0
1 2 3 4 5 6 ... 45 46

Resumo do Conteúdo

Página 1 - Service&MaintenanceManual

iXPanelT70Service&MaintenanceManualEnglishMAEN006,2010-05

Página 2 - Foreword

Installation3Installation3.1 SpaceRequirements• Installation plate thickness: 1.5 - 9.0 mm (0.06 - 0.35 inch)• Space requirements when installing the

Página 3 - Contents

Installation2.Place the panel cut out where the operator panel is to be situated, draw alongthe outer sides of the holes and cut according to the mark

Página 4

Installation4.Connect the cables in the specified order, according to the drawing and stepsbelow.Caution:• Ensurethattheoperatorpanelandthecontrollersy

Página 5 - 1SafetyPrecautions

Installation3.2.1 ConnectionstotheControllerFor information about the cables to be used when connecting the operator panel tothe controller, please re

Página 6 - 1.5 DismantlingandScrapping

Technical Data4TechnicalDataParameter iX Panel T70Frontpanel,WxHxD 219x154x6mmMountingdepth 56mm(156mmincludingclearance)Frontpanelseal IP66Rear panel

Página 7 - 2Introduction

Chemical Resistance5 ChemicalResistance5.1 MetalCasingThe frame and casing material is powder-coated aluminum. This powder paintwithstands exposure to

Página 8 - 2.4 DismantlingandScrapping

Chemical Resistance5.2 TouchScreenandOverlay5.2.1 AutotexF157/207Autotex F157 or F207 covers the overlay surrounding the touch screen.SolventR esistan

Página 9 - 2.5 ContactandSupport

Chemical Resistance5.2.2 TouchScreenSurfaceThetouchscreensurfaceonthepanelwithstandsexposuretothefollowingsolvents without visible change:Solvents Tim

Página 10 - 3Installation

Hardware Tests6 HardwareTestsBefore the operator panels are approved for market introduction, they are testedby independent authorities. The iX Panels

Página 11 - 0.5 - 1.0 Nm

Additional Hardware7 AdditionalHardware7.1 MemoryCardAn internal Compact Flash memory card can be used in iX Panel T70 forexpansion of the project mem

Página 12 - – Connect cable D

ForewordService&MaintenancemanualforiXPanelT70ForewordThis manual contains detailed information about iX Panel T70, includingdescriptions of vario

Página 13 - BeijerElectronics, MAEN006

Additional Hardware5.Re-attach the back cover to the operator panel.6.Turn on the power to the operator panel.When the operator panel starts up, you w

Página 14 - 4TechnicalData

Hardware Replacement8 HardwareReplacementThis section contains instructions on how to replace operator panel hardware.Only components included in the

Página 15 - 5 ChemicalResistance

Hardware ReplacementMODE Description1100 Notused(runmode).1110 Self-test.xxx1 Hardreset(forcesthesystemtorese t).To ch ange mode switches, follow the

Página 16 - 5.2 TouchScreenandOverlay

Hardware Replacement8.3 ReplacingtheRearCoverThe following is needed:• Anewrearcover,seeAvailable Spare Parts for iX Panel T70• AtorxT10screwdriverNot

Página 17 - 5.2.3 AutoflexEB

Hardware Replacement8.4 ReplacingtheDisplay/DisplayCableThe following is needed:• A new display including plastic frame and display cable, seeAvailabl

Página 18 - 6 HardwareTests

Hardware Replacement8.4.1 Self-testoftheDisplayTo perform a self-test of the display, follow the steps below:1.Start the operator panel in a self-test

Página 19 - 7 AdditionalHardware

Hardware Replacement8.5 ReplacingtheCompleteFrontThe following is needed:• Anewfront,seeAvailable Spare P arts for iX Panel T70• AtorxT10screwdriverNo

Página 20 - 7.1.2 SettingsiniXDeveloper

Hardware Replacement8.6 ReplacingtheBacklightIf the backlight of the iX Panel T70 is broken, the entire display must be replaced.To replace the displa

Página 21 - 8 HardwareReplacement

Hardware Replacement8.7 AvailableSparePartsforiXPanelT70Ordernumber Description601009274 COMPLETEFRONTIncludingfrontcover,touchoverlay,gasketsandlabel

Página 22 - 8.2 Cables

Service Menu9ServiceMenuThe service menu for the operator panel can be accessed before a project isdownloaded, or by setting the mode switches in mode

Página 23 - 8.3 ReplacingtheRearCover

ContentsContents1 Safety Precautions ... 51.1 General ...

Página 24 - • AtorxT10screwdriver

Service Menu9.3.3 EraseProjectThe erase function will detect if the project is located in the panel memory or on amemory card. Pressing Erase Project

Página 25 - 8.4.1 Self-testoftheDisplay

Hardware Self Test10 HardwareSelfTestThe self-test program can be used to test aspects of operator panel functionalityand the communication ports. To

Página 26 - 8.5 ReplacingtheCompleteFront

Additional Installation Tips11 AdditionalInstallationTipsWhen experiencing communication problems in for example noisy environmentsor when operating c

Página 27 - 8.6 ReplacingtheBacklight

Additional Installation Tips11.2 EthernetConnectioninthePanel123451-12-23-38-8RJ45RJ45RJ45RJ45RJ45RJ45RJ45RJ45Industrial EthernetOperator panelOperato

Página 28 - Hardware Replacement

Additional Installation Tips11.3 ToAchieveBetterEMCProtection• Initially, use the original cabling from Beijer Electronics primarily.• Use shielded ca

Página 29 - 9ServiceMenu

Additional Installation Tips11.4 AmbientTemperatureThe maximum ambient temperature for the operator panel is provided in thespecifications. The ambient

Página 30 - 9.3.5 TouchCalibrate

Additional Installation Tips11.5 SafetyMost of the operator panels are fed with 24 V DC.412434Power supply230 V AC to 24 V DCPower supply230 V AC to 2

Página 31 - 10 HardwareSelfTest

Additional Installation Tips11.6 GalvanicIsolationUSBUSBRS232RS422/485+24 V DC0 VFilterDC/DCgalvanic isolationVCC0 V (GND)DC/ACCFLEthernetInternal ele

Página 32 - 11 AdditionalInstallationTips

Additional Installation Tips11.7 CableandBusTerminationRS485• Use shielded and twisted pair cable. The pair capacitance may not exceed 52.5pF/m and ar

Página 33

Fault Tracing12 FaultTracingThis section includes different fault scenarios and steps to follow to trace the fault.TheiXPanelT70isnotworkingproperly,a

Página 34 - Shielded cable Shielded cable

Contents9.3.3 EraseProject ...309.3.4 FormatMemoryCard ...30

Página 35 - 11.4 AmbientTemperature

Fault TracingTheiXPanelT70isworking,butoneormorekeysarenotworking1.Check that the flex cables are correctly fitted.2.Replace the front according to the

Página 36 - 11.5 Safety

Software13 SoftwareThis chapter describes how to maintain and update the software in the iX Panels.The chapter includes a general description of the o

Página 37 - 11.6 GalvanicIsolation

Software13.2 UpdateSoftwareWhen an update is available, an e-mail is sent to the distributors. The software isalso available on the manufacturer’s web

Página 38 - Inside operator panel

SoftwareTransferImage1.Double-click on the executable Image Loader file to start the transfer program.2.Follow the instructions.The image transfer proc

Página 39 - 12 FaultTracing

Environmental Aspects14 EnvironmentalAspectsThis chapter includes inform ation about the environmental impact of iX Panels.More information can be fou

Página 40

Environmental Aspects14.3 RecyclingThe operator panels consist largely of aluminum. It is a great advantage in terms ofboth resources and the environm

Página 41 - 13 Software

HEADOFFICE SUBSIDIARIESSWEDEN GERMANY USABeijerElectronicsProductsAB Elektronik-SystemeLauerGmbH&Co. KG BeijerElectronicsInc.Box426 Kelterstraße59

Página 42 - 13.2 UpdateSoftware

Safety Precautions1SafetyPrecautionsBoth the installer and the owner and/or operator of the operator panel must readand understand this installation m

Página 43 - TransferImage

Safety Precautions1.3 DuringUse• Keep th e operator panel clean.• Emergency stop and other safety functions may not be controlled from theoperator pan

Página 44 - 14 EnvironmentalAspects

Introduction2IntroductionThis manual describes how to maintain the iX Panel T70.The functions available in iX Developer depend on which operator panel

Página 45 - 14.3 Recycling

Introduction2.2 MaintenanceCarefully read the instructions before beginning maintenance on the operatorpanel.• Only qualified personnel should carry ou

Página 46

Introduction2.5 ContactandSupportIf you want to report a fault or have a question about the operator panels, pleasecontact your local supplier or fill

Comentários a estes Manuais