Beijer-electronics iX T12C EN Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Painel de controlo Beijer-electronics iX T12C EN. Beijer Electronics iX T12C EN User Manual [fr] [de] Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - InstallationManual

iXT12CInstallationManualEnglishMAEN082D,2013-09

Página 2 - Foreword

Hardware Replacement3 HardwareReplacementThis section contains instructions on how to replace operator panel hardware.Only components included in the

Página 3 - Contents

Hardware Replacement4.Remove the fan by removing the two M4x35 Torx screws.5.Reassemble with new fan and filter in reverse order. Use a maximum torque

Página 4 - 1SafetyPrecautions

Hardware Replacement3.2 Replacingthe2.5”SATAMassStorageThe following is needed:• A new 2.5” SATA mass storage• A T X10 Torx screwdriverNote:Makesureto

Página 5 - 1.5 DismantlingandScrapping

Hardware Replacement5.Remove the hard disk drive from the hard drive connection on the CPUboard.6.Reassemble with the new hard disk drive in reverse o

Página 6 - 2Installation

Hardware Replacement3.3 ReplacingaCompactFlashorCFastMemoryCardThe following is needed:• A new CompactFlash or CFast memory card.• A T X10 Torx screwd

Página 7 - 2.2 InstallationProcess

Hardware Replacement3.4 ReplacingtheBatteryThe following is needed:• A new BR 2032 (or CR 2032) battery.• A Torx screwdriverNote:Makesuretouseadequate

Página 8 - Ethernet

Technical Data4TechnicalDataParameter iXT12CFrontpanel,W×H×D 340×242×79mmCutoutdimensions,W×H324×226mmMountingdepth 72mm(172mmincludingclearance)Stand

Página 9

Technical DataParameter iXT12CPowersupply DCinputrange: 18-32VDC(140W)ATXstandardCE:ThepowersupplymustconformwiththerequirementsaccordingtoIEC60950and

Página 10 - 3 HardwareReplacement

Chemical Resistance5 ChemicalResistance5.1 MetalCasingThe frame and casing material is powder-coated aluminum. This powder paintwithstands exposure to

Página 11 - BeijerElectronics, MAEN082D

Chemical Resistance5.2 TouchScreenandOverlay5.2.1 AutotexF157/207Autotex F157 or F207 covers the overlay surrounding the touch screen.SolventResistanc

Página 12 - 3.2 Replacingthe2.5”SATAMass

ForewordInstallationmanualforiXT12CForewordAll operator panels are developed to satisfy the demands of human-machinecommunication. Built-in functions

Página 13

Chemical Resistance5.2.2 TouchScreenSurfaceThe touch screen surface on the operator panel withstands exposure to thefollowing solvents without visible

Página 14 - MemoryCard

Operator Panel Drawings6 Opera torPanelDrawings6.1 Connectors12345678 9Pos. Connector Description1DVI Externalmonitor2VGA Externalmonitor3 COM3/4 Comm

Página 15 - 3.4 ReplacingtheBattery

Operator Panel DrawingsNote:Inordertoutilizetwocommunicationportsonthesamephysicalport,theY-splitcableCAB109mustbeused.DrawingforexternalcableCAB109(d

Página 16 - 4TechnicalData

Operator Panel Drawings6.3 iXT12COutline224 99max. 8 mm77224234032299BeijerElectronics, MAEN082D23

Página 17 - Technical Data

Operator Panel DrawingsNote:AStepCADfileisavailableonthewebsitewww.beijerelectronics.comBeijerElectronics, MAEN082D24

Página 18 - 5 ChemicalResistance

Additional Installation Tips7 AdditionalInstallationTi psWhen experiencing communication problems in for example noisy environmentsor when operating c

Página 19 - 5.2 TouchScreenandOverlay

Additional Installation TipsNote:Thegroundingwiresshouldbeshortandt heconductorshouldhavealargearea.Along,thingroundingwirehasaveryhighimpedance(resis

Página 20 - 5.2.3 Autotex

Additional Installation TipsA good solution may be to use a shielded Ethernet cable, but to co nnect the shieldat one end only.One option is to break

Página 21 - 6 Opera torPanelDrawings

Additional Installation Tips7.3 ToAchieveBetterEMCProtection• Initially, use the original cabling from Beijer Electronics primarily.• Use shielded cab

Página 22 - Operator Panel Drawings

Additional Installation Tips7.4 AmbientTemperatureThe maximum ambient temperature for the operator panel is provided in thespecifications. The ambient

Página 23 - 6.3 iXT12COutline

ContentsContents1 Safety Precautions ... 41.1 General ...

Página 24

Additional Installation Tips7.5 SafetyMost of the operator panels are fed with 24 V DC.412434Power supply230 V AC to 24 V DCPower supply230 V AC to 24

Página 25 - 7 AdditionalInstallationTi ps

Additional Installation Tips7.6 CableandBusTe rminationRS485• If maximum transfer distan ce and maximum transfer speed is needed,shielded and twisted

Página 26 - OperatorPanel

Additional Installation Tips7.7 BootPriorityThe boot priority is the order in which the hardware storage devices are read.Pressing F7 durin g boot wil

Página 27

Additional Installation Tips7.9 ResetSwitchA reset switch is located under the fan lid.Follow the instructions in chapter Replacing the Fan and Filter

Página 28

HeadofficeBeijerElectronicsABBox42620124Malmö,Swedenwww.beijerelectronics.com/+4640358600

Página 29 - 7.4 AmbientTemperature

Safety Precautions1SafetyPrecautionsBoth the in staller and the owner and/or operator of the operator panel must readand understand this installation

Página 30 - 7.5 Safety

Safety Precautions• Peripheral equipment must be appropriate for the application and location.1.3 DuringUse• Keep the operator panel clean.• Emergency

Página 31

Installation2Installation2.1 SpaceRequirements• Maximum installation plate thickness: 8 mm• Space requirements in millimeters when installing the oper

Página 32 - 7.8 EnteringBIOS

Installation2.2 InstallationProcessThe following is needed:• ATorxTX7screwdriver1.Unpack and check the delivery. If damage is found, notify the suppli

Página 33 - 7.9 ResetSwitch

Installation4.Connect the cables in the specified order, according to the drawing and stepsbelow.Caution:• Ensurethattheoperatorpanelandthecontrollersy

Página 34 - 20124Malmö,Sweden

Installation2.2.1 ConnectionstotheControllerFor information about the cables to be used when connecting the operator panel tothe controller, please re

Comentários a estes Manuais

Sem comentários