Vista de página 18
Hardware Replacement
7 HardwareReplacement
This section contains instructions on how to replace operator panel hardware.
Only components included in the latest bill of material and spare parts list are
allowed. See Available Spare Parts for iX Panel TA100.
7.1 ModeSwitches
The iX Panel TA100 has four mode switches (DIP switches) located on the rear
side of the operator panel.
1
24V DC
CF CARD
COM 1
RS422
RS485
COM 2
RS232
10/100
EXPANSION
BUSY
MODE
1 2 3 4
ON DIP
MODE
1 2 3 4
ON DIP
Warning:
Themodesbelowaretobeusedwithcaution.
Themodeswitcheshavethefollowingfunctions: 1=ON,0=OFF
Each letter in “MODE” has a corresponding mode switch.
MODE Description
0000 “Runmode”-bootsCE,normaloperation.
0010 Notused.
0100 Notused.
1000 ServiceMenumode,theservicemenuforthesystemprogramis
shown. AllowstheusertosetIPconguration,erasetheproject,
calibratethetouchscreen etc. SeesectionServiceMenufordetails.
1100 Notused(runmode).
1110 Selftest.
xxx1 Notused.
To change mode switches, follow the steps bel ow:
1.
Disconnect power from the operator panel.
2.
Set the mode switches using a ballpoint pen.
3.
Reco
nnect power to the operator panel.
BeijerElectronics, MAEN013A