Beijer-electronics SCOM Protocol EN Manual do Utilizador Página 20

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 131
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 19
Command Reference
20 Beijer Electronics, MAEN975
6.2 MAN
Manufacturer ID
Requests the manufacturer ID from the monitor. The manufacturer ID is a short,
max. 7 character ASCII-string containing the manufacturer specific code.
For monitors manufactured by Beijer Electronics, the returned code is always “LAU”.
Supported since Firmware Version
MT230 Nautic Monitor: 1.0
Command Stream
(This command has no data)
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
15
Example
Query the manufacturer ID of the monitor at address 0.7 (group 0, address 7):
The monitor at address 0.7 (group 0, address 7) has returned “0x4C 0x41 0x55”,
which represents the ASCII-string “LAU”, indicating that the monitor is manufac-
tured by Elektronik-Systeme Lauer GmbH & Co. KG:
0 1 2 3 4 5 6
0x07 ADR
0x4D 0x41 0x4E 0x00 ICHKH
0 1 2 3 4 5 6 7...7+[LEN]-1 7+[LEN]
0x06 ADR
0x4D 0x41 0x4E LEN ICHKH Manufacturer ID ICHKD
Manufacturer ID
Value: ASCII characters
Type: String
Length: 0...7
Description: ASCII-string containing the manufacturer ID
0 1 2 3 4 5 6
0x07 0x07 0x4D 0x41 0x4E 0x00 0x15
0 1 2 3 4 5 6 7...9 10
0x06 0x07
0x4D 0x41 0x4E 0x03 0x13 0x4C 0x41 0x55 0x1D
Vista de página 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 130 131

Comentários a estes Manuais

Sem comentários